SMPS Transformers

Custom SMPS and switch-mode transformers on EE/EF/ETD ferrite cores by P&A International

Custom SMPS & Switch-Mode Transformers

Switch-mode supplies live or die on the magnetics. P&A International engineers, prototypes and delivers custom SMPS transformers on EE/EF/ETD/EFD/RM/PQ ferrite cores — flyback, forward, push-pull, half/full-bridge and LLC topologies, 1 W to 3 kW, 20 kHz to 1 MHz+ — built to your schematic, target cost and compliance requirement.

As an engineering-led contract manufacturer founded as an engineering consultancy, we assign one dedicated engineer to your project from DFM review to qualified samples in 10–15 working days, then scale into volume through our vetted partner-factory network, where every supplier is ISO 9000 certified or better.Request a quote ›

Engineering-led since 2008
consultancy + manufacture

One dedicated engineer
per project, end-to-end

10–15-day prototypes
qualified samples with test data

ISO 9000 partner network
every supplier certified or better

24/7 engineering support
one-off to high volume

Why choose PA SMPS transformers

All topologies

Flyback, forward, push-pull, half/full-bridge and LLC — designed for your converter and switching frequency.

Low leakage & loss

Interleaved, sandwiched windings cut leakage inductance and AC/proximity loss for efficiency and EMI.

Safe isolation

Reinforced or triple-insulated wire, creepage/clearance to IEC 62368-1 / 61558, CE and UL as specified.

Built to your spec

EE/EF/ETD/EFD/RM/PQ cores, bobbins and potting selected and DFM-reviewed for your design.

Engineering capability

  • Magnetic design & simulation — turns ratio, leakage inductance, core loss, AL, thermal modelling
  • Core grade selection for power density and loss at your frequency
  • Winding strategy — interleaving / sandwiching — for leakage and AC resistance
  • Safety construction — reinforced / triple-insulated wire; creepage/clearance to IEC 62368-1 and 61558
  • DFM review to hit target cost while preserving performance
  • Built-to-spec compliance (CE / UL / IEC as specified)
  • Qualified samples with full test data before any volume tooling
  • One dedicated engineer owns the project end-to-end

At a glance

Cores EE / EF / ETD / EFD / RM / PQ / planar
Power 1 W – 3 kW
Frequency 20 kHz – 1 MHz+
Topologies Flyback, forward, push-pull, half/full-bridge, LLC
Isolation To CE/UL/IEC 62368-1; reinforced insulation available
Prototype 10–15 working days to qualified samples
Quantities One-off prototypes to high volume
Quality Every supplier in our network is ISO 9000 certified or better

Why engineers & buyers choose PA

For design engineers

A true design partner — one dedicated engineer, full magnetic simulation and DFM support, rapid samples, and SMPS transformers optimised for efficiency, leakage, thermal and EMI. We routinely target leakage-inductance reduction and first-pass DFM approval on LLC resonant converters — not just off-the-shelf parts.

For purchasing

Low-risk scalability — predictable 10–15-day prototypes, flexible MOQ from one-off to production, target-cost DFM, a single point of contact, and a vetted ISO 9000+ partner network managed end-to-end by P&A. No hand-offs, no surprises.

3 easy steps to get started

1

Send us your spec

Send your drawing or spec sheet. One dedicated engineer reviews it and confirms the technical details with you.

2

Proposed design & quote

You receive a proposed design and indicative pricing — typically within 48 hours — to review and refine together.

3

Samples & production

Qualified samples with full test data in 10–15 working days; on approval we scale into volume through our partner network.

Applications

AC-DC & DC-DC power supplies · chargers and adapters · industrial and renewable power · telecom and data infrastructure · LED drivers · energy storage and battery management.

Explore related types: high-frequency & switch-mode magnetics, planar and LAN & signal transformers.

Choosing the right switch-mode transformer

A few decisions shape every SMPS design — sharing this detail lets us quote and prototype faster:

Topology first Flyback for low-power isolated rails; forward for mid-power; push-pull, half- and full-bridge for higher power; LLC for soft-switching and high efficiency. Topology, frequency and I/O voltages set the core and winding.
Core & material EE/EF/ETD/EFD cover most SMPS work; RM and PQ give compact, low-EMI designs; planar suits low-profile high-density. Ferrite grade balances loss, saturation and cost at your frequency.
Leakage & efficiency Interleaving and sandwiching control leakage and AC/proximity loss, which drive efficiency, snubber design and EMI. We model and minimise it.
Thermal headroom Temperature rise comes from core and copper loss; we select bobbin, wire gauge (incl. litz) and potting to stay in your thermal limit.
Isolation & safety Creepage/clearance, reinforced or triple-insulated wire and compliance to IEC 62368-1 / 61558, CE and UL designed in from the start.

What to send us for a fast, accurate quote

The more of this you can share, the quicker we can return a proposed design and price:

  • Schematic or topology, plus switching frequency
  • Input/output voltages, currents and power (turns ratio if known)
  • Isolation and safety requirements, and target standards
  • Mechanical envelope — height, footprint, mounting — and thermal limits
  • Target cost and annual volume or call-off pattern
  • Any reference design, competitor part number or physical sample

Working from a competitor part or a sample is fine — our engineer will reverse-engineer it or design a drop-in equivalent to your specification.

📄 Download the SMPS transformer RFQ checklist & core-selection quick reference (PDF)

Get a quote

Send your schematic, switching frequency, voltages and spec sheet and one dedicated engineer will reply — typically within 48 hours — with a proposed design and indicative pricing.


    Optional: attach a schematic, spec sheet or reference part (PDF, image, ZIP, doc - max 8 MB).

    One dedicated engineer reviews every enquiry and replies with a proposed design and indicative pricing. Your details are used only to respond to your enquiry. Prefer email? support@pa-international.com.au

    Frequently asked questions

    Which topologies and power levels do you cover?
    Flyback, forward, push-pull, half/full-bridge and LLC, from 1 W to 3 kW and 20 kHz to 1 MHz+, on EE/EF/ETD/EFD/RM/PQ and planar cores.
    Can you design from my schematic or a sample?
    Yes – send a schematic and switching frequency, a competitor part number or a sample and our engineer will design to your spec or develop a drop-in equivalent.
    How do you minimise leakage inductance and EMI?
    Interleaved and sandwiched winding, careful core and bobbin choice and screens reduce leakage and AC/proximity loss, which drive efficiency, snubber design and EMI.
    Can you meet IEC 62368-1 / UL safety isolation?
    Yes – reinforced or triple-insulated construction with creepage and clearance to IEC 62368-1 / 61558, CE and UL as specified. Every supplier in our network is ISO 9000 certified or better.
    What are prototype lead times and minimum order quantities?
    Qualified samples with full test data typically in 10-15 working days. Volumes scale through our vetted partner-factory network; share your annual volume for an MOQ with the quote.